Inverters
Solis S6-GC3P(40-60)K-ND — 60K05-HV (Global catalogue)
String inverter · Global catalogue · Output AC / Rated output power: 60 kW
Manufactured by Solis and supplied by EITAI. Confirm the regional version, certification, availability and battery compatibility for the exact model before ordering.
← Back to productsEITAI / PRODUCT INFORMATION
Technical specifications
| Input DC / Max. input voltage | 1100 V |
|---|---|
| Input DC / Rated voltage | 720 V |
| Input DC / Start-up voltage | 180 V |
| Input DC / MPPT voltage range | 180 - 1000 V |
| Input DC / Max. input current | 5 × 42 A |
| Input DC / Max. short circuit current | 5 × 52.5 A |
| Input DC / MPPT number / Max. input strings number | 5 / 10 |
| Output AC / Rated output power | 60 kW |
| Output AC / Max. apparent output power | 60 kVA |
| Output AC / Max. output power | 60 kW |
| Output AC / Rated grid voltage | 3/PE, 480 V |
| Output AC / Rated grid frequency | 50 Hz / 60 Hz |
| Output AC / Rated grid output current | 72.2 A |
| Output AC / Max. output current | 72.2 A |
| Output AC / Power factor | > 0.99 (0.8 leading - 0.8 lagging) |
| Output AC / THDi | < 3% |
| Efficiency / Max. efficiency | 98.7% |
| Efficiency / EU efficiency | 98.1% |
| Protection / DC reverse-polarity protection | Yes |
| Protection / Short circuit protection | Yes |
| Protection / Output over current protection | Yes |
| Protection / Surge protection | DC Type II / AC Type II |
| Protection / Grid monitoring | Yes |
| Protection / Anti-islanding protection | Yes |
| Protection / Temperature protection | Yes |
| Protection / Strings monitoring | Yes |
| Protection / I/V Curve scanning | Yes |
| Protection / Multi peak scan | Yes |
| Protection / Integrated AFCI 2.0 | Optional |
| Protection / Integrated PID recovery | Optional |
| Protection / Integrated DC switch | Yes |
| General Data / Dimensions (W × H × D) | 508 × 612 × 288 mm |
| General Data / Weight | 37.4 kg |
| General Data / Topology | Transformerless |
| General Data / Self-consumption (night) | < 1 W |
| General Data / Operating ambient temperature range | -25 ~ +60°C |
| General Data / Relative humidity | 0 - 100% |
| General Data / Ingress protection | IP66 |
| General Data / Noise emission (typical) | ≤ 55 dB(A) |
| General Data / Cooling concept | Intelligent fan-cooling |
| General Data / Max. operation altitude | 4000 m |
| General Data / Grid connection standard | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126/UTE C 15/VFR:2019, RD 1699/RD 244/UNE 206006/ UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530 |
| General Data / Safety / EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 |
| Features / DC connection | MC4 connector |
| Features / AC connection | OT terminal |
| Features / Display | LED indicator & Bluetooth + APP |
| Features / Communication | Standard: RS485×2; Optional: Wi-Fi, 4G, DRM |
Values may differ by model or system configuration. Published certification and compatibility information must be confirmed for the supplied model.
Official product source
- Manufacturer
- Solis
- Source checked
- Models in this series
- 40K04-NV · 50K04-NV · 60K05-NV · 50K04-HV · 60K05-HV