Inverters
Solis S6-EH2P(9.6-16)K03-SV-YD-L-US — 12K (US)
Hybrid inverter · US · Output AC (Grid side) / Rated output power: 12 kW
Manufactured by Solis and supplied by EITAI. Confirm the regional version, certification, availability and battery compatibility for the exact model before ordering.
← Back to productsEITAI / PRODUCT INFORMATION
Technical specifications
| Input DC (PV side) / Recommended max. PV power | 19.2 kW |
|---|---|
| Input DC (PV side) / Max. input voltage | 550 V |
| Input DC (PV side) / Rated voltage | 380 V |
| Input DC (PV side) / Start-up voltage | 100 V |
| Input DC (PV side) / MPPT voltage range | 100-450 V |
| Input DC (PV side) / Full load MPPT voltage range | 160-450 V |
| Input DC (PV side) / Max. input current per MPPT | 40 A |
| Input DC (PV side) / Max. short circuit current per MPPT | 50 A |
| Input DC (PV side) / Number of MPPTs / Number of strings per MPPT | 3 / 2 |
| Battery / Battery type | Li-ion / Lead-acid |
| Battery / Battery voltage range | 40 - 60 V |
| Battery / Max. charge / discharge current | 250 A |
| Battery / Communication | CAN / RS485 |
| Battery / Number of batteries per inverter | See Battery Compatibility Sheet |
| Output AC (Grid side) / Rated output power | 12 kW |
| Output AC (Grid side) / Max. apparent output power | 12 kVA |
| Output AC (Grid side) / Rated output voltage | 220 V / 240 V |
| Output AC (Grid side) / Rated grid frequency | 50 Hz / 60 Hz |
| Output AC (Grid side) / Rated grid output current | 54.5 A / 50 A |
| Output AC (Grid side) / Max. output current | 54.5 A / 50 A |
| Output AC (Grid side) / THDi | < 3% |
| Input AC (Grid side) / Input voltage range | 193.6 - 242 V / 211 - 264 V |
| Input AC (Grid side) / Max. input current | 200 A |
| Input AC (Grid side) / Frequency range | 59.5 - 60.5 Hz / 58.8 - 61.2 Hz |
| Output AC (Back-up and Off-gird) / Rated output power | 12 kW |
| Output AC (Back-up and Off-gird) / Max. apparent output power | 2 time of rated power, 10 s; 3 times of rated power, 1 s |
| Output AC (Back-up and Off-gird) / Back-up switch time | < 10 ms |
| Output AC (Back-up and Off-gird) / Phase power | L1/L2/N(PE), 120 V / 240 V (split phase) |
| Output AC (Back-up and Off-gird) / Rated output voltage (L1-L2) | 220 V / 240 V |
| Output AC (Back-up and Off-gird) / AC output voltage range | 193.6-242 V / 211-264 V |
| Output AC (Back-up and Off-gird) / Rated grid frequency | 50 Hz / 60 Hz |
| Output AC (Back-up and Off-gird) / Rated output current | 54.5 A / 50 A |
| Output AC (Back-up and Off-gird) / Max. output over current protection, 10 sec | 109 A / 100 A |
| Output AC (Back-up and Off-gird) / Max. continuous AC passthrough | 200 A |
| Output AC (Back-up and Off-gird) / Max. allowable phase imbalance | 50% |
| Output AC (Back-up and Off-gird) / Backup support configurations | Dedicated loads and whole-home |
| Output AC (Back-up and Off-gird) / Power factor | > 0.99 (0.8 leading - 0.8 lagging) |
| Output AC (Back-up and Off-gird) / THDv (@linear load) | < 3% |
| Input Generator / Max. input power | 30 kW |
| Input Generator / Max. input current | 125 A |
| Input Generator / Rated input frequency | 50 Hz / 60 Hz |
| Efficiency / Max. efficiency | 96.02% |
| Efficiency / CEC efficiency | 95.45% |
| Efficiency / Battery charged by PV max. efficiency | 96.21% |
| Efficiency / Battery charged / discharged to AC max. efficiency | 94.16%/94.22% |
| Protection / Ground fault monitoring | Yes |
| Protection / Integrated AFCI | Yes |
| Protection / DC reverse-polarity protection | Yes (PV only) |
| Protection / Rapid shutdown NEC 2017 | Integrated SunSpec-certified Transmitter |
| Protection / Compatible RSD receivers | See MLRSD compatibility Sheet |
| Protection / Protection class / Over voltage category | I / II |
| General Data / Dimensions (W × H × D) | 21.02 × 36.61 × 11.69 in (534 × 930 × 297 mm) |
| General Data / Weight | 145.06 lbs (65.8 kg) |
| General Data / Topology | Transformerless |
| General Data / Operating ambient temperature range | -13°F to 140°F (-25°C to 60°C) |
| General Data / Ingress protection | TYPE 4X (IP66) |
| General Data / Self-consumption (night) | < 35 W |
| General Data / Noise emission (typical) | <65 dB(A) |
| General Data / Cooling concept | Intelligent fan-cooling |
| General Data / Relative humidity range | 0 - 100% |
| General Data / Mounting type | Wall Bracket |
| General Data / Max. operation altitude | 13120 ft (4000 m) |
| General Data / Grid Certifications | IEEE 1547-2018, IEEE1547.1-2020, CA Rule 21, SRD 2.0 |
| General Data / Safety Certifications | UL 1741 PVRSS, UL 1699B, UL 1998 (US), UL 1741, UL 1741 SB, CSA C22.2107.1-1 |
| General Data / Emissions | FCC Part 15 Class B |
| Features / DC connection | Terminal Block (PV port) / Terminal Block (BAT port) |
| Features / AC connection | Terminal Block |
| Features / Interface | 7.0" LCD display & Bluetooth + APP |
| Features / Revenue grade meter | Optional |
| Features / Monitoring platform | SolisCloud (modbus map and API sharing available upon request) |
| Features / Communication | RS485, Optional: Cellular, Wi-Fi, LAN |
Values may differ by model or system configuration. Published certification and compatibility information must be confirmed for the supplied model.
Official product source
- Manufacturer
- Solis
- Source checked
- Models in this series
- 9.6K · 10K · 11.4K · 12K · 14K · 16K